| Details
about 500 MW Power plant |
| Phase
I - 155 MW Captive Power Plant at Hazira |
|
Configuration
One Gas Turbine + One Heat recovery Steam
generator + One Steam Turbine |
|
Technical data / information of major equipment
installed:
The salient technical data of the major equipment
for the Phase - I 155 MW Captive Power Plant at
Hazira are as thus:
|
| Gas
Turbines |
| Manufacturer |
Hitachi
Ltd, Japan |
| Model |
PG 9161E |
| Rating |
100
MW at site conditions
116.9 MW at ISO conditions |
| Type
of fuel fired |
Natural
Gas |
| Generators
for Gas Turbines - 1 |
| Manufacturer |
Hitachi
Ltd, Japan |
| Type |
Horizontal
shaft rotating field totally enclosed Air cooled
generator |
| Rating |
142000
KVA |
| Heat
Recovery Steam Generator - 1 |
| Manufacturer |
Deltak, USA |
| Type |
Dual Pressure, Non
fired, Horizontal flue gas path, natural circulation |
| Capacity |
179 TPH of superheated
HP steam at 91 Bar pressure and 485 deg C temp &
36.27 TPH of super heated LP steam at 5 Bar and
172 Deg C |
| Steam
Turbine - 1 |
| Manufacturer |
Siemens
|
| Type |
Axial
Flow Single cylinder condensing |
| Rating |
55 MW
at Site conditions |
| Speed |
3000
RPM |
| Generator
for Steam Turbine - 1 |
| Manufacturer |
Siemens
|
| Type |
Air
Cooled |
| Rating |
71250
KVA |
| |
|
Phase II & III - 340 MW
Captive Power Plant at Hazira |
Configuration
Two Gas Turbines + Two Heat Recovery Steam Generators
+ One Steam Turbine |
| Technical
data / information of major equipment installed:
The salient technical data related to the
major equipment to be installed in the Phase -
II & III 340 MW Power Plant at Hazira are
given below:
|
| Gas
Turbines - 2 |
| Manufacturer |
Bharath
Heavy Electricals Limited, India |
| Model |
PG 9171E |
| Rating |
108
MW at site conditions
123.4 MW at ISO conditions |
| Type
of fuel fired |
Natural
Gas |
| Generators
for Gas Turbines -2 |
| Manufacturer |
Bharath
Heavy Electricals Limited, India |
| Type |
Air
Cooled Generator |
| Rating |
135000
KVA |
| Heat
Recovery Steam Generator- 2 |
| Manufacturer |
IHI,
Japan |
| Type |
Triple
pressure, Aux fired, Horizontal flue gas path, natural
circulation |
| Capacity |
184
TPH superheated HP steam at 72 Bar pressure and
520 deg C temp, 18.8 TPH super heated IP steam at
21 Bar pressure and 298 deg C & 21.6 TPH super
heated LP steam at 5 bar pressure and 192 deg C |
| Steam
Turbine - 2 |
| Manufacturer |
Siemens
|
| Type |
Axial
Flow Single Cylinder Condensing |
| Rating |
128
MW at site conditions |
| Speed |
3000
RPM |
| Generator
for Steam Turbine - 2 |
| Manufacturer |
Siemens
|
| Type |
Air
Cooled |
| Rating |
162500
KVA |
| Gas
Turbine -3 |
Manufacturer
|
Bharat
Heavy Electricals Limited, India |
| Model |
PG 9171E |
| Rating |
110 MW at site conditions
126.1 MW at ISO conditions |
| Type of fuel fired |
Natural Gas |
| Generators
for Gas Turbine - 3 |
| Manufacturer |
Bharat Heavy Electricals
Limited, India |
| Type |
Air Cooled Generator |
| Rating |
135000 KVA |
| Heat
Recovery Steam Generator - 3 |
| Manufacturer |
Hangzhou Boiler
Group Company, China |
| Type |
Triple pressure,
Un-fired, Horizontal flue gas path, natural circulation |
| Capacity |
183 TPH superheated
HP steam at 71 Bar pressure and 520 deg C temp,
18.5 TPH super heated IP steam at 22 Bar pressure
and 293 deg C & 15.8 TPH super heated LP steam
at 6 Bar pressure and 192 deg C |